WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-671b
MODELS: E21-NG3 Natural Gas E21-LP3 Propane
E21 Gas Insert
03/11/09
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - E21 Gas Insert

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Page 2 - CONGRATULATIONS!

10 Regency® E21-3 Gas Fireplace InsertWIRING DIAGRAMSINSTALLATIONCAUTION: Label all wires prior to disconnection when servicing controls. Wiring er

Page 3 - TABLE OF CONTENTS

11Regency® E21-3 Gas Fireplace InsertNote: Do not operate unit if fl ue connector is not fastened in original position.FLUE CONNECTOR INSTALLATION 1)

Page 4 - SAFETY LABEL

12 Regency® E21-3 Gas Fireplace InsertGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing its indivi

Page 5 - REQUIREMENTS

13Regency® E21-3 Gas Fireplace InsertTEST FOR FLUE SPILLAGEA " spillage" test must be made before the installed unit is left with the custom

Page 6

14 Regency® E21-3 Gas Fireplace InsertLOG SET INSTALLATIONLog kit (Part # 533-930) contains the following pieces: a) 27-23 Back Center Log b) 27-24

Page 7

15Regency® E21-3 Gas Fireplace Insert6) Fit log 27-26 into the pins on the front right side of the burner.5) Rest the top of log 27-25 in the notch

Page 8

16 Regency® E21-3 Gas Fireplace Insert8) Fit log 27-28 into the pin on the left side of the burner.9) Fit the left end of log 27-29 into the pin on

Page 9

17Regency® E21-3 Gas Fireplace InsertCompleted Log Set Installation27-2311) Place embers along the front of the burner as shown. Ensure not to cover

Page 10 - INSTALLATION

18 Regency® E21-3 Gas Fireplace InsertDiagram 4Diagram 56) Connect the ON/OFF switch wires by taking the black and red wires with the female ends an

Page 11

19Regency® E21-3 Gas Fireplace InsertFLUSH GLASS1) Install the bottom glass trim onto the glass support.2) Slide the glass into the bottom glass tri

Page 12

2 Regency® E21-3 Gas Fireplace InsertCONGRATULATIONS!You are the owner of a state-of-the-art Gas Insert by:FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.T

Page 13

20 Regency® E21-3 Gas Fireplace InsertBAY LOUVERS1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay

Page 14

21Regency® E21-3 Gas Fireplace InsertConversion Kit# 534-969 from NG to LPTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO

Page 15

22 Regency® E21-3 Gas Fireplace Insert17) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visib

Page 16

23Regency® E21-3 Gas Fireplace InsertInstaller Notice:These instructions must be left with the appliance.37) Check for gas leaks.38) Check inlet and

Page 17

24 Regency® E21-3 Gas Fireplace InsertFULL SCREEN DOORS1) Hold the full screen door up against the unit in order to make the following wire connecti

Page 18

25Regency® E21-3 Gas Fireplace Insert6) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws each.Bottom FrameHinge L

Page 19

26 Regency® E21-3 Gas Fireplace InsertThermostat Wire TableCAUTIONDo not wire millivolt wall thermostat wiresto 120V wire.WALL SWITCH1) Run the wire

Page 20

27Regency® E21-3 Gas Fireplace InsertFINAL CHECKBefore leaving this unit with the customer, the installer must ensure that the appliance is fi ring cor

Page 21

28 Regency® E21-3 Gas Fireplace InsertOPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS LIGHTING INSTRUCTIONSTO TURN OFF GAS APPLIANCEGas In

Page 22

29Regency® E21-3 Gas Fireplace InsertMAINTENANCE INSTRUCTIONS1) Always turn the gas valve to off before cleaning. For relighting, refer to lighting i

Page 23

3Regency® E21-3 Gas Fireplace InsertTABLE OF CONTENTSSAFETY LABELSerial No. Decal ...4REQUIRE

Page 24

30 Regency® E21-3 Gas Fireplace InsertREMOVING VALVE ASSEMBLY1) Disconnect the power.2) Shut off the gas.3) Remove top and bottom louvers.4) Rem

Page 25

31Regency® E21-3 Gas Fireplace InsertPARTS LISTMAIN ASSEMBLY Part # Description Part # Description 530

Page 26

32 Regency® E21-3 Gas Fireplace InsertBURNER ASSEMBLY & LOG SET Part # Description 533-574/P Valve Assembly-

Page 27 - OPERATING INSTRUCTIONS

33Regency® E21-3 Gas Fireplace InsertPARTS LISTBAY & FLUSH FRONT ASSEMBLY Part # Description Pa

Page 28 - TO TURN OFF GAS APPLIANCE

34 Regency® E21-3 Gas Fireplace InsertFACEPLATE ASSEMBLY Part # Description 91) 910-330 Fan Speed Cont

Page 29 - MAINTENANCE

35Regency® E21-3 Gas Fireplace InsertWARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our interna

Page 30

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 31 - PARTS LIST

4 Regency® E21-3 Gas Fireplace InsertSAFETY LABELThis is a copy of the label that accompanies each Regency® Gas Insert. We have printed a copy of the

Page 32

5Regency® E21-3 Gas Fireplace InsertREQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requir

Page 33

6 Regency® E21-3 Gas Fireplace InsertIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe Regency® Gas Fireplace must be installed in accordance with these

Page 34

7Regency® E21-3 Gas Fireplace InsertINSTALLATION POLICY FOR SOLID FUEL BURNING & FACTORY BUILT FIREPLACESThe Regency® E21 may be installed and ven

Page 35 - WARRANTY

8 Regency® E21-3 Gas Fireplace InsertCLEARANCES TO COMBUSTIBLESINSTALLATION The minimum clearance from the side of the appliance to a combustible sid

Page 36

9Regency® E21-3 Gas Fireplace InsertHIGH ELEVATIONThis unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA 2.17-M91) with the orifi ce suppl