WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-531c
MODELS: U39-NG1 Natural Gas U39-LP1 Propane
ULTIMATE U39
Direct Vent Freestanding Gas Stove
04/05/11
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - Installation Manual

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Page 2

10Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONFor Vent Termination requirements, see "Exterior Vent termination Location

Page 3 - DIMENSIONS

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove11INSTALLATIONEXTERIOR VENT TERMINAL LOCATIONSMinimum Clearance RequirementsCanada1USA2A Clear

Page 4 - TABLE OF CONTENTS

12Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufactur

Page 5 - SAFETY LABEL

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove13INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amer

Page 6 - REQUIREMENTS

14Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONRIGID PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsAlternate Horizonta

Page 7

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove15INSTALLATIONINSTALLATION PRECAUTIONSThese venting systems are engineered products that have

Page 8

16Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONHorizontal Venting with Two (2) 90o Elbows Option V H + H1 A)

Page 9

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove17INSTALLATIONDV STOVE HORIZONTAL VENT KIT INSTALLATIONMinimum Installation Height:U39: 59-3/4

Page 10 - INSTALLATION

18Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATION Note: if the centerline cannot be met, the adjustable sections will have to

Page 11

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove19INSTALLATIONAlternate Horizontal Termination CapsDura-Vent Basic Horizontal Kit1 90o Elbow1

Page 12

2Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveREGENCY®ULTIMATE Direct Vent Freestanding Gas StoveTo the New Owner:Congratulations! You are

Page 13

20Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONNOTE: For Snorkel terminations in ABOVE grade installations, follow national o

Page 14

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove21INSTALLATIONDiagram 10Diagram 9Diagram 8Diagram 7Diagram 67) Install the Wall Thimble in th

Page 15

22Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONDiagram 11: The upper half of the fl ashing is installed under the roofi ng materi

Page 16

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove23INSTALLATION Using a level, make sure the support is vertical. If the support extends abov

Page 17

24Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONConverting a Masonry ChimneyImportant: The existing masonry flue opening needs

Page 18

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove25INSTALLATIONU39-NG1: For 0 to 2000 feet altitudeU39-LP1: For 0 to 4500 feet altitudeBurner I

Page 19

26Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONCONVERSION KIT# 731-969 FROM NG TO LPTHIS CONVERSION MUST BE DONE BY A QUALIFIED

Page 20

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove27INSTALLATION16) Pull off the pilot cap to expose the pilot orifi ce.17) Unscrew the pilot or

Page 21

28Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATION7) Reversing step 2 and secure the control panel back onto the stove pedestal w

Page 22

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove29INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply pipi

Page 23

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove3DIMENSIONS

Page 24

30Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due

Page 25

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove31INSTALLATIONLOG SET INSTALLATIONEmbers EmbersThe "02" refer numbers (i.e. 02-65) a

Page 26

32Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONCutoutPinD)02-46B)02-56A)02-657) Place the Left Top Log D)02-46 on the pin on L

Page 27

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove33INSTALLATIONCutoutNotchF)02-47E)02-45A)02-6511) Place the notch in Center Log F)02-47 over

Page 28

34Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONWIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing c

Page 29

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove35INSTALLATIONThermostat Wire TableOPTIONAL WALL THERMOSTAT A wall thermostat may be installed

Page 30

36Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove36OPERATING INSTRUCTIONSSHUTDOWN INSTRUCTIONS1) Use the Burner ON/OFF switch, thermostat or

Page 31

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove37Regency Gas Fireplace37INSTALLATIONOPERATING INSTRUCTIONS1) Push in gas control knob slightl

Page 32

38Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the valve before cleaning. For religh

Page 33

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove39MAINTENANCEMitred Glass ReplacementRemoving Glass1) Remove the door from the unit and place

Page 34

4Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveTABLE OF CONTENTSDIMENSIONSUnit Dimensions ...

Page 35

40Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan

Page 36 - OPERATING INSTRUCTIONS

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove41MAINTENANCEREMOVING VALVE2) Undo the six screws holding the control panel in place.3) Disc

Page 37

42Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LIST30) 630-021 Fan Access Panel31) 730-019 Rear Panel32) 730-565 Firebox Baffl e/Re

Page 38 - MAINTENANCE

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove43PARTS LISTBURNER & LOG ASSEMBLY51) 910-241 Burner ON/OFF Switch (3-way)52) 910-190 P

Page 39

44Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LISTDOOR ASSEMBLY Part # Description 730-932 G

Page 40

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove45NOTES

Page 41

46Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveNOTES

Page 42 - PARTS LIST

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove47WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In

Page 43

48Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveInstaller: Please complete the following informationDealer Name & Address: _____________

Page 44

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove5SAFETY LABELThis is a copy of the label that accompanies each ULTIMATE Direct Vent Freestandi

Page 45

6Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followi

Page 46

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove7INSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANC

Page 47 - WARRANTY

8Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONIMPORTANT MESSAGESAVE THESE INSTRUCTIONSThe ULTIMATE Direct Vent Freestanding Gas

Page 48

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove9INSTALLATION8) Any safety glass removed for servicing must be replaced prior to operating th