Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
1
Section 1: Introduction
The Model 4734 Control Expander is a plug-on unit that provides greatly enhanced software
features, event storage memory, and user-friendly operation for the Model 4720 Control/Com-
municator. The 4734 replaces the control microprocessor on the 4720 (or on the obsolete
Model 4721 Area Control Software). It allows full use of up to two zone expanders for a sys-
tem maximum of 80 zones.
The 4734 supports the Model 4181 (PL513) Power Line Control Interface, which controls X-
10 modules at various locations, making it possible to turn lamps and other appliances on and
off at preprogrammed times, as the result of touchpad key press or a change in system status.
The Model 4734 hardware is powered by the 4720 hardware and supports the same expansion
devices as the 4720. The 4734 can be added to existing 4720 (or 4721) installations.
1.1 Features
Availability of up to 1000 user codes (or cards) programmable to allow control of
selected functions.
1000 separate users, cards, or codes.
Allows door relays to be bypassed (or latched) open.
Any door can be controlled from any station.
Can report “Access Denied” or “Door Restore” events.
Support of up to 64 expansion zones which have all the same options as internal zones
(except fast loop restore).
Each touchpad panic zone is a separate zone, adding 64 more zones.
Ability to report up to 1000 user codes (or cards), programmable to allow control of
selected functions. Secondary user code (Code 2) option allows codes to be enabled
temporarily for users such as guests and baby-sitters.
High-security code option that requires selected users to enter a second code to gain
access to restricted areas.
32 time windows for programming time restrictions and automatic arming and dis-
arming times. Time windows can also be used to activated X-10 or 4180 auxiliary
outputs.
Holiday schedule can be programmed for 16 holiday dates.
Two dates can be supplied to adjust automatically for daylight savings time.
Event memory that stores at least the last 500 events, including alarms, troubles,
bypasses, restores, openings, closings, and tests.
Use of both door/card access and intercom/phone modules on the same installation.
Each station is selected for either door or intercom operation.
Enhanced access control features such as separate “door access” and “door left open”
timers for each door.
Control of up to 32 standard X-10 Power Line Control Interface Modules. Outputs
can be activated by time events, zone status, alarms, touchpads, or virtually any inter-
nal condition or combination of conditions.
Support of two Model 4180 Status Display Modules for a total of 32 outputs that can
be programmed to annunciate status conditions such as armed, alarm, trouble, and
tests.
Built-in programmer with English-language prompts.
Fully programmable using built-in programmer or Model 5540 Downloading Soft-
ware.
Enhanced split system (area control) capability, allowing separate control of system
functions in up to eight different areas of the building.